Manual Flapper Valve of High Vacuum
1、 Safety instructions
The valve is suitable for working medium of air or low corrosive gas. The operating pressure range is 2 × 105Pa ~ 1.3 × 10-6pa.
2、 Working principle and structural characteristics
The valve can be used as the opening and closing mechanism in the high vacuum pipeline, which can cut off and connect the air flow in the vacuum system. The driving part adopts screw driving lifting valve plate, which is light and reliable.
3、 Performance index
Opening and closing mode: Manual
Standard of connecting flange: GB / T 4982 GB / T 6070
Suitable range: 10-6pa ~ 2 × 105Pa
Applicable medium: air or low corrosive gas
Valve body leakage rate: < 1.3 × 10-7pa · L · S-1
Valve plate forward and reverse leakage rate: < 1.3 × 10-7pa · L · S-1
Service life: > 200000 times
Installation position: DN < 300 any, DN ≥ 300 vertical
Within the allowable pressure range, the valve can be opened or closed in different differential pressure directions;
The opening height of the valve is arbitrary, and the air flow can be adjusted.