Manual Flapper Valve of High Vacuum

SaveSavedRemoved 0
Deal Score0
Deal Score0

1、 Safety instructions

The valve is suitable for working medium of air or low corrosive gas. The operating pressure range is 2 × 105Pa ~ 1.3 × 10-6pa.

2、 Working principle and structural characteristics

The valve can be used as the opening and closing mechanism in the high vacuum pipeline, which can cut off and connect the air flow in the vacuum system. The driving part adopts screw driving lifting valve plate, which is light and reliable.

3、 Performance index

Opening and closing mode: Manual

Standard of connecting flange: GB / T 4982 GB / T 6070

Suitable range: 10-6pa ~ 2 × 105Pa

Applicable medium: air or low corrosive gas

Valve body leakage rate: < 1.3 × 10-7pa · L · S-1

Valve plate forward and reverse leakage rate: < 1.3 × 10-7pa · L · S-1

Service life: > 200000 times

Installation position: DN < 300 any, DN ≥ 300 vertical

Within the allowable pressure range, the valve can be opened or closed in different differential pressure directions;

The opening height of the valve is arbitrary, and the air flow can be adjusted.