Possible Failures of Butterfly Valves and Their Elimination Methods
SaveSavedRemoved 0
Deal Score0
Fault: Leakage on both ends of the valve
- The sealing gaskets on both sides fail,
- The pipe flange has uneven or not compressed pressure.
Elimination method:
- Replace the sealing gasket.
- Tighten the flange bolts (evenly).
Butterfly valve failure: leakage of sealing surface
- There are debris in the butterfly plate and sealing ring of the butterfly valve.
- The butterfly plate of the butterfly valve and the closed position of the seal are not correct.
- The outlet is equipped with flange bolts that are not compressed or stressed.
- The direction of the pressure test is not as required.
Elimination method
- Eliminate impurities and clean the inner cavity of the valve.
- Adjust the limit screws of actuators such as worm gears or electric actuators. In order to achieve the correct closing position of the valve.
- Check the mounting flange plane and bolt compression force, and they should be evenly compressed.
- Spinning in the direction of the arrow
These two kinds of faults are generally encountered by butterfly valves. You can eliminate the faults according to this method.